- MULTI-PARCAN-54x3W-RGBW
User’s Manual
Thank you for using our LED PAR light 54x3W RGBW, for your safety, please read the user`s manual carefully before your operation.
Note: This manual includes the important information of installation, operation,
safety instruction. Please install and operate as requested in the manual, meanwhile, please keep the manual for any unexpected requirment
- Preface
This Manual includes the important information of installation and operation. Please install and operate the light according to the instructions strictly. And it must be power off when open the light or before repair.
Please read the complete contents of this manual(please keep this manual attach with the light for any preview) In order to make sure the correct and safety installation、operation and maintenance, well know and follow to the instructions of Manual is necessary.
We will not take any responsibility to the light damage、property loss or body injure which caused by the incorrect installation、operation and maintenance.
Notice:
The data which inside the Manual maybe changed due to continuous improvement, and we’ll not make another notice. We will keep the right to any specification update during improvement
Waring: the light should keep away from fire and water to avoid it get into light.
Packing Content
One LED PAR 54x3W RGBW One DMX cable
User manual
Note: Please check if all the contents are completed after unpacking, then, check if the light is undamaged.
Safety specifications
This device is for indoor use only,the protection grade is: IP20
Installing of the light must keep a distance from any flammable objects by 5m at least. The distance between the light and the projected objects must be no less than 1m.
Please never directly install the light on the surface of the flammable objects.
The installation、operation and maintenance must be managed by the qualified professional, and make sure to operate it under the instruction of the Manual.
Make sure the work environment temperature of the light maximum 35℃, and minimum -20℃
The temperature of the light surface will be up to 60℃ even under normal cooling, so never touch it by hand. The light was designed by electric shock protection type and must connect to the power supply system which is well earthed. Furthermore, the ground wire of the light must connect to the ground wire of the power supply system, ground wire interface of the light must well connect with the light body (or light must be well earthed) Please check if the voltage is in accordance with the rated power before installing.
Please never use the power cable which was damaged the insulation cover, meanwhile, never put the power cable on any other wire. Please pull out the power cable by handle the plug when the light stops working or cleaning, never pull out it roughly or handle the wire directly.
The light doesn’t include any spare parts for repairing, please check if all the parts are well installed and screws are drove tightly before operating. It’s prohibited to use the light when the cover is opened.
Notice: Please make sure it is power off before any installation, repair and clean
- TechnologyParameter
Control Channels: 8 DMX Channels
- eamAngel:25°
- ontrolMode:AUTO, Master/Slave, DMX512, Sound Active Working Environment: Indoor, -20℃-40℃
Mixing Color: RGBW mixing color
IP Grade: IP20
Power Supply: AC 100-240V/50-60Hz
LED Unites: 54pcs x 3W (RGBW)
Power consumption:150W
Packing size: 25×25×36cm 79×52×38.5cm(6pcs/CTN) N/W: 2.9KG(1pc/CTN) G/W:; 19KG(6pc/CTN)
III. Connection of power/wire/signal
The exclusive plug should be used between the connection of light and power. Pls, check if the rated voltage and frequency are in accordance with the power supply. In order to make sure the power cable work in the safe environment. If found the power cable overheats, please cut off the power and reduce the parallel connection quantity of lights, The light power supply is AC100~AC240V/50~60Hz
Make sure the installation position is steady before fix the light. A professional clamp should be used when the light is reverse hanging, and drive the clamp into the screw hole in the bracket of the light. Make sure the light will not fall from the truss, use the safety cable to go through the truss and bracket of the light as a supporting, to avoid the light falling down. There is no entrance to the work area during mounting. Periodically to check if the safety cable has fretted away or the clamp is loosened. We will not take any responsibility caused by the lighting fall of unsteady hanging. Warning:
It is prohibited to move the light by handle the clamp, please move the light by handle
IV. Features:
There are 4 buttons and 4 bit of digital LED on the panel, you can choose different working mode via press the buttons, and it will display one the digital-led
The fan running is automatical controlled by temperature, when the temperature is higher than 60℃, the fan will run, when the temperature is lower than 55℃, the fan will stop running.
V.Description
Mode Up Down Enter
- Buttonspecifications
- >.Button“Mode”, change the operating mode
- >.Button“Up”, change the operating mode of the submenu or add the value
- >.Button“Down”, change the operation mode of the submenu or subtract the value
- >.Button“Enter”, for confirmation
2.“DMXADD” setting
Press button Mode to d.XXX, XXX is the value of ADD 001-512, it’s the ADD code of this light, press “Up”, “Down” to adjust it (range: 001-512), save automatically after setting.
3. Work“Mode” setting
The light includes 5kinds of work modes, the default mode is d.001, press the button “Mode”, it’s available to choose in DMX mode, Auto mode, Edit mode, Slave mode, Load the default mode.
Display
- >.DisplayXXX(XXX is 001-512 ADD code), DMX mode, can receive standard DMX signal, press button “Up” or “Down” to change the ADD code, and save automatically after setting.
- >.Display” Auto”, master under “Auto” mode, it’s available to enter into “Auto” mode selection by press button “Enter”, at this moment, display “XX”, “XX” is code 01-11, which means 11 kinds of dynamic and static mode, it’s available to recycle chose one of the modes by pressing the button “Up” or “Down”.
Display “Edit”, under master editing mode, it’s available to enter into “Edit” mode selection by pressing button “Enter”, at this moment, display “Pr.0X”, “X” is code 1-5, which means internal 5 kinds of selectable mode, it’s available to recycle chose one of the modes by pressing the button “Up” or “Down”. Press the button “Enter” under a mode, it’s available to recycle change the brightness of the RGB LED.
- >.Display“Slav”, slave mode, receive the synchronous data from
- >.Display“Load”, press button “Enter”, to load the default date
VI.Operation
VII. DMX Channel Form
DMX Channel | DMX Value | Functions |
CH1 | 0-255 | Red dimming (from darkness to brightness) |
CH2 | 0-255 | Green dimming (from darkness to brightness) |
CH3 | 0-255 | Blue dimming (from darkness to brightness) |
CH4 | 0-255 | White dimming (from darkness to brightness) |
CH5 | 0-255 | General dimming (from darkness to brightness) |
CH6 | 0-3 | No function |
4-255 | Color changing (from slow to fast) | |
CH7 | 0-3 | No function |
4-255 | Strobe (from slow to fast) | |
CH8 | 0-128 | Sound Mode 1 (sensitive from low to high) |
129-255 | Sound Mode 2 (sensitive from low to high) |
VIII. Appendix
The light is available to receive the DMX512 signal, connect the DMX connector to the panel marked with “DMX IN”,and connect it to the next light. then, connect to the “DMX IN” of the next light from the “DMX OUT”. The DMX signal terminator is recommended when the lighting signal is connecting. It will avoid interfering with the signal caused by the electrical noise, DMX terminator is an XLR connector, connect with a 120Ω resistor between pin 2 and pin 3 of the XLR connector, and connect it to the OUTPUT socket of the final light. see picture:
IX.FaultyDisposal
Familiar Faulty | Disposal |
No display when power is on | 1. Check if the power cable is correctly connected |
2. Check the power supplier is correctly connected | |
Light is out of control | 1. Check if DMX address code is correctly set |
2. Check if the DMX cable is correctly connected | |
The light is off after working for a while | 1. The temperature of working environment is too high and caused overheat protection. |
The beam is dark obviously | 1. Check if the temperature is too high, and cause a fast fade |
2. Check if there is too much dust on the surface of light |
Familiar Faulty | Disposal |
No display when power is on | 1. Check if the power cable is correctly connected |
2. Check the power supplier is correctly connected | |
Light is out of control | 1. Check if DMX address code is correctly set |
2. Check if the DMX cable is correctly connected | |
The light is off after working for a while | 1. The temperature of working environment is too high and caused overheat protection. |
The beam is dark obviously | 1. Check if the temperature is too high, and cause a fast fade |
2. Check if there is too much dust on the surface of light |
Note:
Please contact the supplier or ask for professional repair if it’s still doesn’t work when excluded the above faulty.